The angle stop valve is the small valve on the wall behind your toilet or under your sink, the one with the oval handle that shuts off the water to a single fixture. Most people never touch it until something goes wrong, and then they discover it is leaking. A drip from the valve wastes water every day, and the slow leak can rot the floor or the cabinet underneath before anyone notices. The good news is that most angle stop leaks are fixed with a wrench and a few dollars of parts, and you can do it yourself in under an hour. Here are five simple steps to fix a leaky angle stop valve.
1. Find Exactly Where the Water Is Coming From
Before you touch anything, dry the valve completely with a towel and watch where the water appears. A drip from around the valve stem, the small shaft under the handle, means the packing inside the valve is worn, which is the most common leak and the easiest to fix. A drip from the nut where the valve meets the wall pipe means the connection has loosened, while water from the joint where the supply line meets the valve points to the supply line nut. Knowing the source decides the fix, so take a minute to watch. Put a dry paper towel under the valve and check it after ten minutes; the wet spot will show you exactly which joint is leaking.
2. Shut Off the Main Water and Relieve the Pressure
Even a small valve repair goes wrong if the water is still on, so shut off the main water supply to the house first. The main shut-off is usually near the water meter, in the basement, or where the water line enters the house. Turn it clockwise until it stops, then open the faucet at the fixture you are repairing, and open a faucet at the lowest point in the house, so the water in the pipes drains out and the pressure drops. Keep a towel and a small bucket under the valve while you work, since a little water will always remain in the line. Never try to unscrew a valve fitting while the line is pressurized; the water will spray and you risk stripping the threads. A dry, depressurized line is a safe line to work on.
3. Tighten the Packing Nut First
Most angle stop leaks come from the packing nut, the nut right behind the handle that squeezes a small ring of packing material around the valve stem. Hold the valve body steady with one wrench, and turn the packing nut clockwise about a quarter turn with a second wrench. That is often enough to stop the drip, since the nut simply worked loose over years of use. Turn the water back on and check: if the drip has stopped, you are done, and the whole repair took five minutes. If it still drips, turn the water off again and tighten another quarter turn, but stop there. Overtightening the packing nut makes the handle stiff and can crack the nut, which turns a five-minute fix into a replacement job. If two quarter turns do not stop the leak, the packing itself is worn and needs to be replaced.
4. Repack the Valve or Replace the Washer
If tightening did not work, unscrew the packing nut completely and pull out the old packing, which is usually a small ring of graphite string or a rubber washer sitting around the stem. Take the old packing to the hardware store so you can match it, or buy a small pack of graphite packing string, which fits most valves. Wind the new packing around the stem in the same direction the nut turns, two or three wraps, and push it into place with a small screwdriver. Screw the packing nut back on and tighten it gently until the handle turns with a little resistance but still moves smoothly. If the leak is at the supply line connection instead, unscrew the supply line nut, check the rubber washer inside it, and replace it if it is flattened or cracked.
5. Replace the Whole Valve If It Still Leaks
Some valves are too far gone to save, and replacing one is still a straightforward job. If the valve is a compression fitting, hold the valve body with one wrench and unscrew the compression nut behind it, then slide the old valve off the copper pipe. If it is a threaded valve, unscrew it from the wall pipe counterclockwise, and wrap the threads of the new valve with Teflon tape, three or four wraps in the direction the valve will turn. Slide the new valve on, tighten the compression nut by hand plus a quarter turn with a wrench, or screw the threaded valve on until it is snug and the outlet points up. Turn the main water back on slowly, open the new valve, and check every joint with a dry paper towel. A new quarter-turn ball valve is the best replacement, since it shuts off with a simple twist and its seal lasts far longer than the old multi-turn style.
A leaky angle stop valve is annoying, but it is one of the most forgiving plumbing repairs you can do yourself. Find where the water is coming from, shut off the main and relieve the pressure, tighten the packing nut first, repack the valve or replace the washer, and replace the whole valve if it still leaks. Five simple steps, and the valve that dripped all day will be dry, along with the floor underneath it.